Analysis of the Variation of Exposure Factors on the Contrast-to-Noise Ratio (CNR) of Antero-Posterior Projection Cranium Images

Authors

  • Wahdini Hanifah Universitas Baiturrahmah
  • Nerifa Dewilza Universitas Baiturrahmah
  • Chairun Nisa Universitas Baiturrahmah
  • Sagita Yudha Universitas Baiturrahmah
  • Keisya Salsabila Kirana Universitas Baiturrahmah

DOI:

https://doi.org/10.53861/lontarariset.v7i1.590

Keywords:

Contrast to Noise Ratio, Cranium, Image Quality

Abstract

The quality of radiographic images is highly dependent on exposure factors including tube voltage (kV), tube current and exposure time (mAs). The Contrast to Noise Ratio value can transmit image quality, a higher CNR indicates a good image with less interference (noise). The study aims to determine the effect of exposure factor variations on the CNR value and which exposure factors that produce optimal CNR in AP cranium projections. This study uses a quantitative method, an experimental study at the Radiology Installation of the Siti Rahmah Padang Islamic Hospital in September 2024. Data were obtained from cranium phantom images with variations in tube voltage (kV) 68, 74, and 78, and current and exposure time (mAs) 10, 12, and 14. The images were analyzed using the Radiant DICOM Viewer application with the ROI technique to calculate the CNR value in the anatomical area, namely the frontal, crista gali, mandible, both orbits and the background. The ROI results were analyzed using multiple linear regression tests. The results showed that the variation of exposure factors had a significant effect on the CNR value of 94.7%. The optimal exposure factor, at 68 kV and 14 mAs, with the highest CNR of 44.598. The lowest CNR value at an exposure factor of 78 kV and 10 mAs was 22.063. These results can be used as a reference in determining the optimal exposure factor in AP cranium examination

Downloads

Download data is not yet available.

References

Bushong, S. C. (2017). Radiologic Science for Technologists: Physics, Biology, and Protection (Eleventh). Elsevier.

Damayanti, O., Anggraeni, L. A., & Ningrum, S. A. (2020). Variasi Faktor Exsposi Pada Pemeriksaan Schedel Proyeksi Anterior Posterior untuk Hasil Radiografi yang Maksimal di Rumah Sakit Al Islam Bandung. Jurnal Teras Kesehatan, 3(1), 33–39. https://doi.org/https://doi.org/10.38215/jutek.v3i1.47

Desai, N., Singh, A., & Valentino, D. . (2010). Practical Evaluation of Image Quality in Computed Radiographic(CR).

Dwinanto, B. (2010). Teknik Radiografi Kepala.

Louk, A. ., & Gede, B. . (2014). Pengukuran Kualitas Sistem Pencitraan Radiografi Digital Sinar-X. Berkala MIPA, 24, 146–166.

Pianykh, oleg S. (2014). Digital Image Quality in medicine. Springer International Publishing. https://doi.org/10.1007/978-3-319-01760-0

Prayoga, Nugrahaning, A., Suraningsih, N., & Puspita, M. I. (2022). The Effect of Exposure Factors on Radiographic Image Quality on Thorax Phantom With Pa Projection. urnal Ilmu dan Teknologi Kesehatan, 13(1), 22–26.

Rasad, S. (2015). Radiologi Diagnostik. Badan Penerbit FKUI.

Sari, O. P. (2021). Fisika Radiasi.

Wahyuni, S. (2017). Pengaruh tegangan tabung (kV) Terhadap Kualitas Citra Radiografi Pesawat sinar-X Digital Radiography (DR) pada phantom Abdomen.

Wita, A., & Fransiska, E. (2018). Pengaruh Faktor Eksposi dengan Ketebalan Objek pada Pemeriksaan Foto Thorax Terhadap Gambaran Radiografi. Journal of Health, 5(1), 17–21.

Downloads

Published

2026-01-15

How to Cite

Wahdini Hanifah, Dewilza, N., Nisa, C., Yudha, S., & Kirana, K. S. (2026). Analysis of the Variation of Exposure Factors on the Contrast-to-Noise Ratio (CNR) of Antero-Posterior Projection Cranium Images. Lontara Journal of Health Science and Technology, 7(1), 30–38. https://doi.org/10.53861/lontarariset.v7i1.590

Issue

Section

Research article